TITRO4 Automatic Potential Titrator


5.324,00

TITRO4 Automatic Potential Titrator

  • Automatic potential titration
  • DET / MET / SET / MAT modes
  • pH 0.00–14.00 | mV ±1800
  • RSD ≤ 0.2%
  • Burette 10 / 20 mL
  • GLP, RS-232 / USB

High-precision titrator with LCD display, guided operation, and multiple titration modes for acid–base, redox, precipitation, and complexometric methods. Supports GLP-compliant data storage and full PC connectivity for automated control and reporting.

General Features

  • LCD display screen and smart guide system for intuitive operation.
  • Titration methods, curves and results are displayed in detail on screen.
  • Replaceable high-accuracy burette (10 mL or 20 mL selectable).
  • Supports DET, MET, SET and MAT titration modes.
  • Built-in pH calibration and measurement function.
  • Store up to 50 titration data sets (GLP compliant) and one latest titration curve.
  • Data transfer via RS-232 communication; full PC control via USB or RS-232.

Titration Modes Explained

The TITRO4 supports four main titration modes, each designed for specific analytical workflows and levels of precision:

  • DET – Dynamic Equivalence Point Titration: The titrator automatically adjusts the dosing rate as the equivalence point approaches, ensuring fast and accurate detection. Ideal for acid–base, redox, and complexometric titrations requiring maximum precision.
  • MET – Monotone Equivalence Point Titration: The system doses in fixed, equal steps without adapting to the signal slope. Suitable for method validation and applications requiring reproducible, linear dosing behavior.
  • SET – Preset Endpoint Titration: The titration stops automatically when a pre-defined potential (mV) or pH value is reached. Commonly used for routine analyses with known endpoints, such as chloride or acidity determinations.
  • MAT – Manual Titration: Manual dosing controlled by the operator while the titrator continuously records potential and calculates results. Useful for teaching, method development, and electrode testing.

Together these four titration modes make the TITRO4 versatile for a wide range of chemical, environmental, and pharmaceutical analyses, ensuring both flexibility and reproducibility under GLP standards.

Included Components

  • 10 mL burette
  • 232-01 reference electrode
  • 213-01 platinum electrode
  • 216-01 silver electrode
  • 217-01 reference electrode
  • 231-01 pH indicator electrode
  • T-818-B-6 temperature probe
  • NIST pH standard solutions (4.01, 7.00, 10.01), 50 mL/vial

Technical Specifications

Model Ti-40
Repeatability ≤ 0.2%
Burette Accuracy 10 mL ±0.025 mL; 20 mL ±0.035 mL
Mechanical Unit Resolution 1/14000
Measuring Range mV: −1800.0 to +1800.0; pH: 0.00–14.00
Resolution 0.1 mV; 0.01 pH
Accuracy pH ±0.01; mV ±0.05% FS
Fluctuation ±0.3 mV / 3 h
Temperature Compensation Range −5.0 to 105.0 ℃
Temperature Resolution / Accuracy 0.1 ℃ / ±0.3 ℃
Power Supply AC Adapter 100–240 V input, DC 24 V output
Dimensions 340 × 400 × 400 mm
Weight 10 kg (Net); 12 kg (Gross, carton 540 × 490 × 480 mm)

Application Summary

The TITRO4 Automatic Potential Titrator delivers professional accuracy for laboratories requiring automated titration processes. It is suitable for acid–base (aqueous and non-aqueous), redox, precipitation, and complexometric analyses. Common applications include water alkalinity, acidity of beverages, chloride content by Mohr/Volhard methods, and metal ion determination by EDTA titration. Ideal for routine quality control in food, pharmaceutical, petrochemical, and environmental laboratories.


SKU: PRO6103 Category: