VIKING-EC300 Laboratory Conductivity Meter
Note: Includes PRO6154 EC electrode, 1413 μS/cm standard (50 mL), and EHO5 (PRO6110) electrode stand.
Highlight: IP54 protection, GLP-compliant storage (500 sets per parameter), USB/RS-232 connectivity.
Key Features
- 7.0″ high-resolution LCD with backlight.
- Multi-reading modes: Auto Read (Fast/Medium/Slow), Timed, Continuous.
- Automatic/Manual Temperature Compensation (ATC/MTC); endpoint Auto-Hold with Reading/Stable/Locked prompts.
- GLP-compliant data storage: 500 results for each parameter.
- USB & RS-232 outputs for PC/printer; date & time stamping; auto shutdown 1–60 min (or Off).
- 1–3 point calibration with standard recognition (84 μS/cm, 1413 μS/cm, 12.88 mS/cm).
- Settable cell constant, temperature coefficient, and TDS factor; temp. compensation types (none, linear, pure water).
- IP54 protection.
Included
-
- PRO6154 EC electrode
- 1413 μS/cm EC standard solution, 50 mL (1 vial)
- EHO5 electrode stand (PRO6110)
Specifications
| Parameter | Value |
|---|---|
| Model | VIKING-EC300 |
| Measured Parameters | EC / Resistivity / TDS / Salinity / Temperature |
| Conductivity Range | 0.000 μS/cm ~ 1000 mS/cm |
| Conductivity Resolution | 0.001 μS/cm minimum (varies by range) |
| Conductivity Accuracy | ±1.0% FS |
| Reference Temperature | 20, 25 °C |
| Calibration Points | Up to 3 (standards recognition at 84 μS/cm, 1413 μS/cm, 12.88 mS/cm) |
| Resistivity Range | 5.00 Ω·cm ~ 20.00 MΩ·cm |
| Resistivity Resolution | 0.01 Ω·cm minimum |
| Resistivity Accuracy | ±1.0% FS |
| TDS Range | 0.00 ppm ~ 300 ppt |
| TDS Resolution | 0.01 ppm minimum (varies by range) |
| TDS Accuracy | ±1.0% FS |
| Salinity Range | 0.0–80.0 ppt; 0.00–8.00 %NaCl |
| Salinity Resolution | 0.1 ppt; 0.1% |
| Salinity Accuracy | ±2 ppt |
| Temperature Range | −5.0 to 110 °C (23.0 to 230 °F) |
| Temperature Units | °C, °F |
| Temperature Resolution | 0.1 |
| Temperature Accuracy | ±0.2 °C |
| Reading Modes | Auto Read (Fast/Medium/Slow), Timed, Continuous |
| Prompts | Reading / Stable / Locked |
| Temp. Compensation | ATC, MTC; types: none, linear, pure water |
| Data Storage | 500 results each parameter (GLP features) |
| Inputs | Conductivity with temp probe, 5-pin aviation connector |
| Outputs | USB, RS-232 (PC/printer) |
| Backlight | Yes |
| Auto Shutdown | 1–60 min, Off |
| IP Rating | IP54 |
| Date & Time | Yes |
| Power | AC adapter, 100–240 V AC input; DC 20 V output |
| Dimensions (Instrument) | 242 × 195 × 68 mm |
| Net Weight | 900 g (1.98 lb) |
| Dimensions (Carton) | 350 × 280 × 220 mm |
| Shipping Weight | 2.5 kg |








There are no reviews yet.