VIKING-EC300 Laboratory Conductivity Meter
Note: Includes PRO6154 EC electrode, 1413 μS/cm standard (50 mL), and EHO5 (PRO6110) electrode stand.
Highlight: IP54 protection, GLP-compliant storage (500 sets per parameter), USB/RS-232 connectivity.
Key Features
- 7.0″ high-resolution LCD with backlight.
- Multi-reading modes: Auto Read (Fast/Medium/Slow), Timed, Continuous.
- Automatic/Manual Temperature Compensation (ATC/MTC); endpoint Auto-Hold with Reading/Stable/Locked prompts.
- GLP-compliant data storage: 500 results for each parameter.
- USB & RS-232 outputs for PC/printer; date & time stamping; auto shutdown 1–60 min (or Off).
- 1–3 point calibration with standard recognition (84 μS/cm, 1413 μS/cm, 12.88 mS/cm).
- Settable cell constant, temperature coefficient, and TDS factor; temp. compensation types (none, linear, pure water).
- IP54 protection.
Included
- PRO6154 EC electrode
- 1413 μS/cm EC standard solution, 50 mL (1 vial)
- EHO5 electrode stand (PRO6110)
Specifications
Parameter | Value |
---|---|
Model | VIKING-EC300 |
Measured Parameters | EC / Resistivity / TDS / Salinity / Temperature |
Conductivity Range | 0.000 μS/cm ~ 1000 mS/cm |
Conductivity Resolution | 0.001 μS/cm minimum (varies by range) |
Conductivity Accuracy | ±1.0% FS |
Reference Temperature | 20, 25 °C |
Calibration Points | Up to 3 (standards recognition at 84 μS/cm, 1413 μS/cm, 12.88 mS/cm) |
Resistivity Range | 5.00 Ω·cm ~ 20.00 MΩ·cm |
Resistivity Resolution | 0.01 Ω·cm minimum |
Resistivity Accuracy | ±1.0% FS |
TDS Range | 0.00 ppm ~ 300 ppt |
TDS Resolution | 0.01 ppm minimum (varies by range) |
TDS Accuracy | ±1.0% FS |
Salinity Range | 0.0–80.0 ppt; 0.00–8.00 %NaCl |
Salinity Resolution | 0.1 ppt; 0.1% |
Salinity Accuracy | ±2 ppt |
Temperature Range | −5.0 to 110 °C (23.0 to 230 °F) |
Temperature Units | °C, °F |
Temperature Resolution | 0.1 |
Temperature Accuracy | ±0.2 °C |
Reading Modes | Auto Read (Fast/Medium/Slow), Timed, Continuous |
Prompts | Reading / Stable / Locked |
Temp. Compensation | ATC, MTC; types: none, linear, pure water |
Data Storage | 500 results each parameter (GLP features) |
Inputs | Conductivity with temp probe, 5-pin aviation connector |
Outputs | USB, RS-232 (PC/printer) |
Backlight | Yes |
Auto Shutdown | 1–60 min, Off |
IP Rating | IP54 |
Date & Time | Yes |
Power | AC adapter, 100–240 V AC input; DC 20 V output |
Dimensions (Instrument) | 242 × 195 × 68 mm |
Net Weight | 900 g (1.98 lb) |
Dimensions (Carton) | 350 × 280 × 220 mm |
Shipping Weight | 2.5 kg |
There are no reviews yet.