 RT+5 °C to 160 °C


Overview

The SACO100A is a nitrogen blowdown sample concentrator that uses a high-purity aluminum block with PID control to heat tubes uniformly while directing dry N2 across the liquid surface. Parallel evaporation shortens turnaround for residue analysis, food & environmental testing, and pharmaceutical QC.

Working principle

A warmed block plus directed nitrogen reduces the boundary layer and boosts mass transfer at the surface. Needles are positioned a few millimeters above the liquid to drive evaporation without bubbling or aerosolization. Temperature, total flow, and time are controlled for consistent endpoints.

Applications

  • Concentration of SPE/elution fractions prior to GC/LC.
  • Pesticide, mycotoxin, veterinary drug, and general residue workflows.
  • Food/flavor extracts; environmental water/soil eluates.
  • General solvent removal with parallel throughput and temperature control.

Operation (quick start)

  1. Select the proper block insert (tube diameter) and preheat to set temperature.
  2. Load tubes; set the timer (1–99 h 59 min or continuous ∞).
  3. Lower needles so tips are ~5–10 mm above the liquid surface.
  4. Open the regulator and set total N2 flow; fine-tune if rows are split.
  5. Monitor volume; adjust temperature/flow to avoid bumping or splashing.
  6. At endpoint, close gas, lift needles, and remove tubes with PPE.

Technical specifications

Temperature rangeRT+5 °C to 160 °C
Temperature accuracy±0.5 °C (@40 °C); ±1 °C (@120 °C)
Temperature uniformity±0.5 °C
Display accuracy0.1 °C
Timer1–99 h 59 min / ∞
Heat-up time≤15 min (25 °C → 160 °C)
Needle length150 mm
Max gas usage15 L/min (dry, oil-free N2)
Recommended gas pressure≤16 needles: ~0.02 MPa; >16 needles: ~0.05 MPa
Block quantity1 aluminum block (interchangeable inserts)
Max power300 W
VoltageAC 220 V or 110 V, 50–60 Hz
Dimensions (W×D×H)260 × 220 × 450 mm
Weight7.0 kg

Block options / tube formats

ModelTube diameter / typeQuantity
PRO4585Ø10 mm24
PRO4518Ø12 mm24
PRO4519Ø13 mm24
PRO4520Ø15 mm16
PRO4521Ø16 mm16
PRO4522Ø19 mm12
PRO4523Ø20 mm12
PRO4524Ø26 mm8
PRO4525Ø28 mm4
PRO4526Ø40 mm3
PRO45291.5 mL centrifuge tube24
PRO45302.0 mL centrifuge tube24

Installation & safety

  • Operate under a fume hood; handle flammable/toxic solvents with care.
  • Supply dry, oil-free nitrogen with regulator and flowmeter; check fittings regularly.
  • Wetted parts: stainless-steel needles and PTFE tubing (verify solvent compatibility).

Maintenance

  • Clean/replace needles periodically; inspect O-rings and tubing.
  • Verify flow stability and temperature calibration at routine intervals.
  • Keep the block free of spills and debris to preserve uniformity.
Note: SACO100A is a nitrogen blowdown concentrator (not a vacuum centrifugal concentrator). For vacuum concentration needs, see the “Vacuum Concentrators” category.
SKU: PRO4584 Category: Tag:
Magnetic Stirrers

,

Temp range: RT.+5°C -160°C
Temp accuracy: ±0.5℃(@40℃)
Temp accuracy: ±1℃(@120℃)
Temp uniformity: ±0.5℃
Display accuracy: 0.1℃
Time Range: 1-99h59min/∞
Heating time: ≤15min(from 25℃ to 160℃)
Max vertical travel: 150mm
Max gas usage: 15L/min
Max gas pressure: 0.05Mpa
Block qty: 1
Max power: 500W
Voltage: AC220V or AC110V/50~60Hz
Size: 220x310x385mm
Weight: 7.5kg