SACO100A-Sample Concentrator
Overview
The SACO100A is a nitrogen blowdown sample concentrator that uses a high-purity aluminum block with PID control to heat tubes uniformly while directing dry N2 across the liquid surface. Parallel evaporation shortens turnaround for residue analysis, food & environmental testing, and pharmaceutical QC.
Working principle
A warmed block plus directed nitrogen reduces the boundary layer and boosts mass transfer at the surface. Needles are positioned a few millimeters above the liquid to drive evaporation without bubbling or aerosolization. Temperature, total flow, and time are controlled for consistent endpoints.
Applications
- Concentration of SPE/elution fractions prior to GC/LC.
- Pesticide, mycotoxin, veterinary drug, and general residue workflows.
- Food/flavor extracts; environmental water/soil eluates.
- General solvent removal with parallel throughput and temperature control.
Operation (quick start)
- Select the proper block insert (tube diameter) and preheat to set temperature.
- Load tubes; set the timer (1–99 h 59 min or continuous ∞).
- Lower needles so tips are ~5–10 mm above the liquid surface.
- Open the regulator and set total N2 flow; fine-tune if rows are split.
- Monitor volume; adjust temperature/flow to avoid bumping or splashing.
- At endpoint, close gas, lift needles, and remove tubes with PPE.
Technical specifications
Temperature range | RT+5 °C to 160 °C |
---|---|
Temperature accuracy | ±0.5 °C (@40 °C); ±1 °C (@120 °C) |
Temperature uniformity | ±0.5 °C |
Display accuracy | 0.1 °C |
Timer | 1–99 h 59 min / ∞ |
Heat-up time | ≤15 min (25 °C → 160 °C) |
Needle length | 150 mm |
Max gas usage | 15 L/min (dry, oil-free N2) |
Recommended gas pressure | ≤16 needles: ~0.02 MPa; >16 needles: ~0.05 MPa |
Block quantity | 1 aluminum block (interchangeable inserts) |
Max power | 300 W |
Voltage | AC 220 V or 110 V, 50–60 Hz |
Dimensions (W×D×H) | 260 × 220 × 450 mm |
Weight | 7.0 kg |
Block options / tube formats
Model | Tube diameter / type | Quantity |
---|---|---|
PRO4585 | Ø10 mm | 24 |
PRO4518 | Ø12 mm | 24 |
PRO4519 | Ø13 mm | 24 |
PRO4520 | Ø15 mm | 16 |
PRO4521 | Ø16 mm | 16 |
PRO4522 | Ø19 mm | 12 |
PRO4523 | Ø20 mm | 12 |
PRO4524 | Ø26 mm | 8 |
PRO4525 | Ø28 mm | 4 |
PRO4526 | Ø40 mm | 3 |
PRO4529 | 1.5 mL centrifuge tube | 24 |
PRO4530 | 2.0 mL centrifuge tube | 24 |
Installation & safety
- Operate under a fume hood; handle flammable/toxic solvents with care.
- Supply dry, oil-free nitrogen with regulator and flowmeter; check fittings regularly.
- Wetted parts: stainless-steel needles and PTFE tubing (verify solvent compatibility).
Maintenance
- Clean/replace needles periodically; inspect O-rings and tubing.
- Verify flow stability and temperature calibration at routine intervals.
- Keep the block free of spills and debris to preserve uniformity.