Deals of the Month
DRYSA30 Laboratory Drying Oven Natural Conv. 30L
455,00€Product Carousel Tabs
ALEMADR-MSC Laboratory Dry Block Thermo Shaker Incubator
0°C to 100°C
DESCRIPTION
Designed for simultaneous heating and mixing of small samples, can be supplied with interchangeable blocks for microtubes. Mixing, heating and cooling modes can be used either simultaneously or independently. The main body of the Mixing Block can be used with different kinds of blocks
On Sale Products
VIKING-EC500 Laboratory Conductivity Meter
EC/Temp. (Resistivity/ TDS/Sal.)
EC Range 0.000 μS/cm ~ 2000 mS/cm , Accuracy ±0.5% FS
Resistivity Range 5.00 Ω·cm ~ 100.00 MΩ·cm , Accuracy ±0.5% FS
TDS Range 0.000 ~ 1000 g/L, Accuracy ±0.5%FS
Salinity Range (0.00 ~ 8.00)% , Accuracy ±0.1%
Temp. Range -10 ~ 135 ºC, 14 ~ 275 ºF , Accuracy ±0.1
VIKING-EC600 Conductivity Meter
EC/Temp. (Resistivity/ TDS/Sal.)
EC Range 0.000 μS/cm ~ 3000 mS/cm ,
Accuracy ±0.5%FS
Resistivity Range 5.00 Ω·cm ~ 100.00 MΩ·cm ,
Accuracy ±0.5%FS
TDS Range 0.000 mg/L ~ 1000 g/L , Accuracy ±0.5%FS
Salinity Range (0.00 ~ 8.00)% , Accuracy ±0.1%
Temp. Range -5 ~ 130 ºC , Accuracy ±0.1
VIKING-EC510 Portable EC/Resistivity/Temp/TDS/Sal/
Electro Conductivity Range
EC Range 0.000 μS/cm ~ 3000 mS/cm ,
Accuracy ±0.5% FS
Resistivity Range 5.00 Ω·cm ~ 100.00 MΩ·cm ,
Accuracy ±0.5% FS
TDS Range 0.000 ~ 1000 g/L ,
Accuracy ±0.5%FS
Salinity Range (0.00 ~ 8.00)% , Accuracy ±0.1%
Temp. Range -10 ~ 135 ºC, 14 ~ 275 ºF ,
Accuracy ±0.1
VIKING-PH110 Portable pH (mV) Meter MTC
pH composite electrode
NIST pH standard solution(4.01,7.00, 10.01) , 50ml/vial
Electrode holder
Silicone rubber case
Wristbands
pH Range -0.00 ~ 14.00 ,
Accuracy ±0.03 pH
mV Range -1400 ~ 1400 mV ,
Accuracy ±0.2%F
Calibration Points(1~2)
NIST Standard Recognition
Packing Include:
pH composite electrode
NIST pH standard solution(4.01,7.00, 10.01) 50ml/vial
Electrode holder
Silicone rubber case
Wristbands
VIKING-PH310F Portable pH/Temp (mV) with 3 in 1 Electrode
Accurate-Powerful
Auto-Read (Fast, Medium,
Slow), Timed-Read, Continuous-read
GLP Features
500 groups data sets
Print, PC
Packing include:
3 in 1 pH composite electrode
NIST pH standard solution(4.01,7.00, 10.01) , 50ml/vial
Electrode holder
Silicone rubber case
Wristbands
Carrying Case
VIKING-PH310T Portable pH/Temp (mV) with 3 in 1 Electrode
Accurate-Smart
Touchscreen
1000 groups data sets
Print, PC
Packing include:
3 in 1 pH composite electrode
NIST pH standard solution(4.01,7.00, 10.01), 50ml/vial
Electrode holder
Silicone rubber case
Wristbands
Touch pen
Carrying Case
VIKING-PH200 Benchtop pH Meter pH/Temp. (mV)
Reliable-Durable
ATC
Auto-Read, Continuous-read
Reading Prompts
50 groups data sets
pH Range -2.00 ~ 18.00 pH ,
Accuracy ±0.01 pH
mV Range -1999 ~ 1999 mV ,
Accuracy ±0.1%FS
Temp. Range -5 ~ 110 ºC, 23 ~ 230 ºF ,
Accuracy ±0.2
Calibration Points(1~3)
NIST Standard Recognition
VIKING-PH300 Benchtop pH Meter pH/Temp. (mV)
Calibration Points(1~5)
NIST, GB , DIN Standard
Recognition
Standard Customization
pH Range -2.00 ~ 20.00pH ,
Accuracy ±0.01 pH mV Range -2000.0 ~ 2000.0 mV ,
Accuracy ±0.3 mV or ±0.1%
Temp. Range -5~110 ºC, 23~ 230 ºF ,
Accuracy ±0.2
Bestellers

Some Products to Complete Your Laboratory
MBINCO50 Laboratory CO2 Incubator 50 Liter
Sensitive far infrared CO2 sensor and automatic calibration function brings about accurate control of CO2 concentration.
● HEPA filter installed inside ensures the inner air quality reaches level 100.
● Breeze circulation system brings no effect to the cell culturing.
● When the door is open, the fan will stop to keep from the convection of internal air and external air, and heating system will stop to prevent over temperature.
● Direct 6-side heating wire heating, and air jacket design bring about short warming up time, no over temperature, and good uniformity.
● SUS304 Cu mirror stainless steel chamber with foursquare arc transition design can keep from bacteria and experiment contamination.
● Bottom heating natural evaporation humidification plate ensures high humidity culturing environment
● Hidden UV lamp sterilizes the water in the humidification plate and the circulating air to make the experiment environment clean.
● double layer door design: reinforced glass internal door makes sure the scalability.
● Adjustable direction of door opening meets different custom users.
● Internal door heating system keeps from moisture condensing.
● Air inlet HEPA DUF filters dust of which diameter is larger than 0.33 um with efficiency of 99.97%, and minimize the pollution in the working chamber.
● Over-temperature alarm, CO2 concentration abnormality alarm, and warning water level alarm.
● Convenient PID operation: running with data set and time set, automatic shut-down based on setting, and automatic recovery to previous status after power outage and recovery .
● Special function key for temperature setting.
● Auxiliary menus make over-temperature alarm, deviation adjusting, and menu lock c